Phase II Subsurface Investigation at a Child-Occupied Facility in Gary, Indiana
A child-occupied facility in Gary, Indiana, needed to know whether past activities on and around its property had left contamination behind. A Phase I environmental site assessment (Phase I ESA) had identified several potential environmental concerns. Because the facility frequently serves children, those concerns warranted further investigation.
Aegis Environmental scoped and completed a targeted Phase II investigation to test each concern.
Project at a glance
| Item | Detail |
|---|---|
| Property | Child-occupied facility on approximately one acre |
| Location | Gary, Indiana |
| Trigger | Potential environmental concerns identified in a Phase I ESA |
| Service | Phase II subsurface investigation |
| Media sampled | Soil, groundwater, soil gas, indoor air, and interior dust |
The Situation
The Phase I ESA pointed to two sources of potential concern:
- Former indoor shooting range. Possible residual lead contamination inside the building.
- Nearby former businesses. Potential migration of contaminants from former auto repair, dry-cleaning, and filling station properties.
Evaluating them meant looking at the ground beneath the property, vapors that could move toward the building, and surfaces inside it.
How Aegis Scoped the Investigation
Aegis designed the Phase II subsurface investigation to evaluate each pathway directly:
- Soil and groundwater. Three soil probes, with sampling for volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), and lead.
- Soil gas and indoor air. Three exterior soil-gas sampling points and one indoor air sample, analyzed for VOCs.
- Interior dust. Six lead dust-wipe samples collected inside the former shooting range.
What the Investigation Found
Aegis compared soil, groundwater, and soil-gas results with applicable published levels from the Indiana Department of Environmental Management (IDEM), and dust results with the EPA dust-lead action level.
| Pathway | Result |
|---|---|
| VOCs and PAHs | Not identified above applicable IDEM published levels at the sampled locations |
| Lead in soil | One location above the residential published level, but below commercial and excavation-worker levels |
| Dissolved lead in groundwater | Below applicable levels |
| VOCs in exterior soil gas | Below published levels |
| Lead in dust, former shooting range | Four of six wipe samples above the EPA dust-lead action level |
If a Phase I ESA has flagged concerns on a property you are responsible for, speak with an Aegis project manager about the next appropriate step for your site.
What Aegis Recommended
Aegis matched each recommendation to a specific finding:
- Lead in soil. Further investigation to assess lead in soil.
- Former shooting range. Thorough cleaning, followed by lead-clearance sampling.
- Rest of the building. Consideration of additional dust-wipe sampling.
Dust-wipe and soil sampling for lead are part of Aegis’s commercial lead investigation and testing services.
What the Client Gained
The investigation separated concerns that require further attention from potential concerns that did not exceed applicable levels. The client can now direct its next steps toward the lead findings.
Aegis explained the significance of the results and how each recommendation followed from the data.
Plan Your Phase II investigation with Aegis
A Phase II scope should fit the property and the questions your Phase I ESA raised. Contact Aegis to discuss the property, project objectives, schedule, and scope.
FREQUENTLY ASKED QUESTIONS
What does a Phase II subsurface investigation involve?
It generally involves collecting and analyzing samples to learn more about conditions a Phase I ESA flagged. The scope depends on site conditions and the decisions the client needs to make.
Does a Phase II investigation mean cleanup will be required?
Not necessarily. Here, several potential concerns did not exceed applicable levels at the sampled locations, while the lead findings led to specific recommendations. Next steps depend on the results and site conditions.
Why sample dust as well as soil and groundwater?
Some concerns sit inside the building. At a former indoor shooting range, residual lead may be on interior surfaces, which soil and groundwater samples would not capture.
How much does a Phase II investigation cost?
Cost depends on scope, including the number of sampling points, the media sampled, and whether drilling is needed. Contact Aegis for project-specific pricing.